Vue de la page 0
PVC Channel
Site Sizable Series
Installation Instructions
The Site Sizeable Series intended for use with traditional waterproong methods:
°
Hot Mop
°
Copper Pan
°
Rubber Liner (Chloraloy®)
°
PVC Liner
°
Lead Pan
°
Fiberglass
Dimension are subject to Manufacturers tolerance and change without notice. We can assume no responsibility for
use of superseded or void data.
Las dimensiones están sujetos a la tolerancia del fabricante y cambio sin previo aviso. No podemos asumir ninguna
responsabilidad por el uso de datos a sustituir los nulos.
S-TIF 6540
S-TIF 6548
S-TIF 6560
S-TIF 6580
S-TIF 6596
S-TIF 65
S-AG 3836
S-AG 3848
S-AG 3860
S-AG 3896
S-AG 38
S-AG 10048
S-AG 10096
S-AG 100
S-DG 3848
S-DG 3860
S-DG 3896
S-DG 38
S-DG 6548
S-DG 6560
S-DG 6596
S-DG 65
S-AG 6536
S-AG 6548
S-AG 6560
S-AG 6596
S-AG 65
Infinity Drain18 Secatoag Avenue, Port Washington, New York 11050
Phone 516.767.6786 Fax 516.740.3066 www.InfinityDrain.com
Made in the U.S.A.
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - Site Sizable Series

PVC ChannelSite Sizable SeriesInstallation InstructionsThe Site Sizeable Series intended for use with traditional waterproong methods: ° Hot Mop °

Page 2 - Series Components:

2S-AG 38 SeriesA 3836 36″ Stainless Steel GrateA 3848 48″ Stainless Steel GrateA 3860 60″ Stainless Steel GrateG 3836 36″ PVC ChannelG 3848 48″ P

Page 3

3S-AG38/S-DG38/S-AG65/S-DG65/S-AG100/S-TIF65 kits DO NOT include a mechanically fastening clamp down drain due to the disparity of material of each co

Page 4 - Instalación

4OPTIONAL PROCEDURE:When drain install is required to be ush against the nished wall, build out wall with backer board over round clamp down drain b

Page 5 - (C) Stop End – E38/E65/E100

56b. ONLY FOR S-AG65/S-DG65/S-TIF65/S-AG100 Install: Using a 2-1/4” hole saw, cut a hole through the base of the PVC channel at the desired outlet loc

Page 6

6Note: Minimum height: 1⅝” Maximum height with standard nipple (S50): 2¾” Tenga en Cuenta: Altura Mínima: 1⅝” Altura Máxima con niple: (S50): 2¾” PVC

Page 7

732 Tooth per Inch Blade Hacksaw(A) Top Grate – TA655 Inches32 Tooth per Inch Blade Hacksaw(A) Top Grate – TA65Desired Length2ONLY FOR S-TIF65 INS

Page 8

815. To cover the visible edge of the PVC chan-nel (B), use sandpaper to rough the channel’s top edge. Use a bead of a epoxy based silicone that this